PQ3198-94  - Hioki Taiwan  Sales

BRAND Hioki
Product PQ3198-94
Description power quality analyzer
Internal code IMP4461128
Technical specification Dimensions (width W x height H x depth D) (mm)300×211×68 Instruction manual x 1, measurement guide x 1, voltage cord L1000 x 1 (red/yellow/blue/gray, black x 4, alligator clip x 8), spiral tube x 20, color clip, AC adapter Z1002 x 1, strap ×1, USB cable (1 m) ×1, battery pack Z1003 ×1, SD memory card 2GB Z4001 ×1, application software (PQ ONE) ×1 set contentPQ3198 ×1, AC flexible current sensor CT7045 ×4, carrying case C1009 ×1, branch cord L1021-02 ×3 AC adapter Z1002 (100 to 240 V, rated 1.7 A, 50/60 Hz), battery pack Z1003 (180 minutes of continuous use, charging by connecting to the AC adapter, charging time of 5 hours and 30 minutes) display6.5-inch TFT color LCD (640 x 480 dots) SD/SDHC memory card, LAN (HTTP server function/FTP function), USB 2.0 (communication) 1. Transient voltage: 2MHz sampling, 2. Frequency 1 wave: Calculated from 1 waveform, 200kHz sampling, 3. Voltage 1/2 effective value: Calculated for each waveform with half-wave shift, Current 1/2 effective value: Calculated for each half-wave. , 4. Swell/dip/instantaneous power failure: Detected at 1/2 voltage effective value, 5. Inrush current: Detected at 1/2 current effective value, 6. Voltage waveform comparison: Automatically generate and compare judgment areas, 7. Instantaneous flicker value: According to IEC61000-4-15, 8. Frequency 200 ms: Calculated from 10 waves and 12 waves 40 to 70 Hz, 9. Frequency 10 seconds: Calculated from 10 seconds waveform 40 to 70 Hz, 10. Voltage waveform Peak, current waveform peak, 11. Voltage, current, active power, apparent power, reactive power, active energy, reactive energy, power factor, displacement power factor, voltage unbalance factor, current unbalance factor, efficiency, 12. High-order harmonics (voltage/current): 2k to 80kHz band, 13. Harmonics/phase angle (voltage/current), harmonic power: 0th to 50th, 14. Harmonic voltage-current phase difference: 1st 15. Total harmonic distortion rate (voltage/current), 16. Interharmonics (voltage/current): 0.5th to 49.5th, 17. K factor (multiplication factor), 18. ΔV10 flicker, IEC Flicker (short term/long term) In addition to single-phase 2-wire/single-phase 3-wire/three-phase 3-wire/three-phase 4-wire, voltage/current/power measurement (DC or AC) is also possible on channel 4. ch1~3: Voltage measurement 600.00 Vrms, transient measurement 6.0000 kVpeak, ch4: 600.00 Vrms or DC, transient measurement 6.0000 kVpeak RoHS Directive (compatible with 10 substances)correspondence Maximum/Repeated ON: 1 year, Maximum recorded event: 9999 x 366 days (up to 9999 events per day), Repeated OFF: 35 days, Maximum recorded event: 9999 power range300.00 W to 3.0000 MW (automatically determined depending on the voltage and current range used) Current rangeAC 500.00 mA to 5.0000 kA (measurement range varies depending on the sensor used) Basic accuracyVoltage: ±0.1% of nominal voltage, current: ±0.1% rdg. ±0.1% fs + current sensor accuracy, active power: ±0.2% rdg. ±0.1% fs + current sensor accuracy Calibration certificateGeneral calibration

Please Contact Us to Order to offer competitive prices and delivery time for Hioki - PQ3198-94 power quality analyzer number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Taiwan Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Hioki

LR8401-20

Memory HiLogger

PW3332

Table Type Power Analyzer

PW3335

Table Type Power Analyzer

L2020

test line

L9094

Output Crod

3158

Withstanding Voltage Tester

3159-01 OR 3174

HIGH VOLTAGE DEVICE

Z2001

Temperature Sensor

dt4212 obsolete

Multimetre

3274

Current Probe

3269

Power supply

IM3536

LCR meter

L-2000

4-terminal probe

9830

PC CARD 2G

Other Category Brands

Contact us for request