BRAND | Moore Industries |
Product | SPA²/TPRG/2PRG/U[DIN] |
Description | Digital programmable isolated alarm with indicator |
Internal code | IMP3776348 |
Weight | 0.6 |
Technical specification | MIB-E-SPA017 Configurable alarmtrip SPA²/TPRG/2PRG/U[DIN] Digital programmable isolated alarm with indicator Model : SPA/TPRG/2PRG/U/DIN input : A. All RTD sensors, 2, 3 or 4 wire according to DIN, ASA or JIS (eg. Pt100, Pt200, Pt300, Pt400, Pt500, Pt1000, Ni120, Cu10) selectable B. Differential temperature measuring C. Average temperature measuring with 2 or 3 resistance sensors D. 0-4000 Ohm resistance E. All T/C types according to ISA, selectable. Cold junction compensation : on/off switchable F. mV input : -10 to +120 mV range : all ranges possible, selectable between -200 to +1820°C output : 2 SPDT contacts, 5A 250 V, adjustable over full scale and selectable as high or low, failsafe or NON-failsafe alarm. Relay condition indicated with red/green LED power : universal 90 to 260 Vac and 22 to 300 Vdc accuracy : ± 0,03% F.S. versus actual temperature ambient temperature : -40 +85°C input, output and power are galvanic isolated CMR 120 dB with 1000 VRMS burnout protection : In case of an open input or sensor break : - input LED changes to red - display indicates exact information on what failure has occured - upscale (UD) or downscale drive (DD),selectable - UD & DD ditermines the reaction of the relay outputs eg. with UD all high alarms will switch with DD all low alarms will switch - analogue output follows UD or DD (if AO-option is installed) equiped with digital LCD indicator displaying the real measured temperature and set point value adjustments and calibration : four, front panel push buttons, control settings for Zero, Span, Alarm Trip point, ect. without the need for any other device, thanks to the internal reference source protection : internal jumper and menu password protect parameter settings standard RFI/EMI protection according to SAMA PMC 33.1d30 V/m ABC 0,5% housing : aluminium module for DIN rail mounting |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Moore Industries - SPA²/TPRG/2PRG/U[DIN] Digital programmable isolated alarm with indicator number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Taiwan Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Spring Kit for Valve Positioner model 74 (including spring and screw)
Gauge kit for model 74
Single Loop Controller Manufacturer : Moore Industries Type : 535 Model : 535-2115-00B00 Input : universal Output 1 : 4-20mA Output 2 : mechanical relay Output 3 : mechanical relay Output 4 : loop power Supply : 90-250Volt, ac Housing : panel mounted Option Included : remote set point
Single Loop Controller Manufacturer : Moore Industries Type : 535 Model : 535-2115-00000 Input : universal Output 1 : 4-20mA Output 2 : mechanical relay Output 3 : mechanical relay Output 4 : loop power Supply : 90-250Volt, ac Housing : panel mounted Option Included : none
Single Loop Controller Manufacturer : Moore Industries Type : 535 Model : 535-2115-00D00 Input : universal Output 1 : 4-20mA Output 2 : mechanical relay Output 3 : mechanical relay Output 4 : loop power Supply : 90-250Volt, ac Housing : panel mounted Option Included : set of five digital inputs
Single Loop Controller Manufacturer : Moore Industries Type : 535 Model : 535-2115-0B000 Input : universal Output 1 : 4-20mA Output 2 : mechanical relay Output 3 : mechanical relay Output 4 : loop power Supply : 90-250Volt, ac Housing : panel mounted Option Included : remote set point
Model : IPT2/4-20MA/3-15PSIG/20PSI/-FA7 [DIN] Input : 4-20mA Output : 3-15psig Supply : 20psi Accuracy : ± 0,25% F.S. Ambient temp. range : -40 to 80°C RFI effect : 50V/m@20-1000MHz Mounting position : negligible, unit can be mounted in any position Housing : aluminium module, without mounting block *Standard complete RFI/EMI immune.
IPT2 (data sheet 5.11) Input : 4-20mA Output : 3-15psig Supply : 20psi Accuracy : ± 0,25% F.S. Ambient temp. range : -40 to 80°C RFI effect : 50V/m@20-1000MHz Mounting position : negligible, unit can be mounted in any position Housing : aluminium module for DIN-rail mounting *Standard complete RFI/EMI immune. *Self-sealing connection, by mounting block and supply headers contain self-sealing valves which offers quick release and no air loss.
(AC Power Transducer Manufacturer : Moore Industries Type : PWT (datasheet 15.20) Model : PWT/600AC,5A/4-20MA/1E/-50H-CE [DM] Connection : 1 element Input : 600Volt, 5 Ampere Output : 4-20mA Housing : DIN rail mounting)
Connection : 1 element Input : 600Volt, 5 Ampere Output : 4-20mA Aux. power : 170 – 300Volt, ac Housing : DIN rail mounting
Measurement of active power converter PWT (input voltage (V) 600AS, input Current 5A, 4-20mA output, external power supply (V) 240AS)
SIL 3 Compliant Safety Signal Isolator and Splitter, 4-Wire
ELPRO COLINEAR
TELEMETRY SYSTEM SERVER,
Frequency Converter with Display
USB Configuration Cable Including Software
USB Link
HCS Hart Concentrator System
Non-Isolated Fuse Protected USB Communication Cable
Smart Hart Loop Interface and Monitor
Field-Mount Explosion-Proof Current-to-Pressure Transmitter