BRAND | CD AUTOMATION |
Product | RC3060-45AE0O0011 |
Description | Universal three-phase thyristor controller |
Internal code | IMP4016359 |
Technical specification | mit integrierter Sicherung, im Bereich von 30 A bis 800 A. Typ: RC3060-45AE0O0011 RC3A-BCDEFGHIJK (A) Laststrom H x B x T (Gewicht) 030: 30 A 121 x 144 x 185 mm ( 2,4 kg) 035: 35 A 121 x 144 x 185 mm ( 2,4 kg) 040: 40 A 121 x 144 x 185 mm ( 2,4 kg) 060: 60 A 269 x 279 x 170 mm (10,2 kg) 090: 90 A 273 x 279 x 170 mm (10,6 kg) 120: 120 A 273 x 279 x 170 mm (10,6 kg) 150: 150 A 273 x 279 x 170 mm (10,6 kg) 180: 180 A 273 x 279 x 170 mm (10,6 kg) 210: 210 A 273 x 279 x 170 mm (10,6 kg) 300: 300 A 440 x 520 x 270 mm (22,0 kg) 400: 400 A 440 x 520 x 270 mm (22,0 kg) 450: 450 A 440 x 520 x 270 mm (22,0 kg) 500: 500 A 440 x 520 x 270 mm (22,0 kg) 600: 600 A 560 x 411 x 270 mm (51,6 kg) 700: 700 A 560 x 411 x 270 mm (51,6 kg) 800: 800 A 560 x 411 x 270 mm (51,6 kg) * Abmessungen und Gewicht gelten nicht für 690 V (B) Max. Lastspannung 4: 480 V 6: 600 V 7: 690 V (C) Hilfsspannung 1: 100/120 V AC / 90 bis 135 V AC 2: 200/208/230/240 VAC / 180 bis 265 V AC 3: 277 V AC / 238 bis 330 V AC 5: 380/415/480 VAC / 342 bis 528 V AC 6: 600 VAC / 540 bis 759 V AC 7: 690 VAC / 540 bis 759 V AC (D) Eingang S: SSR (Logik) B: 0 bis 20 mA A: 4 bis 20 mA V: 0 bis 10 V K: 10 KOhm Potentiometer (E) Betriebsart / Start Option B: Burst Firing / ohne Softstart J: Burst Firing / linearer Softstart P: Phasenanschnitt / ohne Softstart E: Phasenanschnitt / linearer Softstart D: Delayed Triggering / ohne Softstart Z: Nulldurchgangsschalter / ohne Softstart R: Nulldurchgangsschalter / linearer Softstart (F) Rückführung 0: ohne / offen U:Spannung / U Q: Spannung Quadrat / U² I: Strom / I A: Strom Quadrat / I² W: Leistung / U x I (G) Option: I-Limit / HB-Alarm / LOGGING / Totalizer 0: - - - - 1: - - - X 2: - - X - 3: - - X X 8: - X - - 9: - X - X A: - X X - B: - X X X G: X - - - H: X - - X I: X - X - J: X - X X O: X X - - P: X X - X Q: X X X - R: X X X X (H) Lüfterspannung 0: ohne Lüfter, bis 60 A 1: 110 V Lüfter, ab 90 A 2: 220 V Lüfter, ab 90 A (Standardausf.) 3: 24 V DC, ab 90 A (I) Zulassungen 0: CE (für den europäischen Markt) L: cUL (J) Lastart 0: 3 PH, ohmsche Last, Sternschaltung mit N 1: 3 PH, ohmsche Last, Dreieck- oder Sternschaltung 2: 3 PH, kurzwellige Infrarotstrahler, Sternschaltung mit N 3: 3 PH, kurzwellige Infrarotstrahler, Dreieck- oder Sternschaltung 4: 3 PH, Trafolast, ohmsche Last angeschl. 5: 3 PH, Trafolast, Kaltleiter angeschlossen (K) Kommunikation / Stetigausgang 0: ohne / ohne 1: N1 Modbus RTU / 4 bis 20 mA 2: N1 Modbus RTU / 0 bis 10 V 3: N2 Modbus RTU / ohne 4: N2 Modbus RTU / 4 bis 20 mA 5: N2 Modbus RTU / 0 bis 10 V 6: N1 Profibus DP / ohne 7: N1 Profibus DP / 4 bis 20 mA 8: N1 Profibus DP / 0 bis 10 V 9: N1 Profibus IO / ohne A: N1 Profibus IO / 4 bis 20 mA B: N1 Profibus IO / 0 bis 10 V C: N1 Modbus TCP / ohne D: N1 Modbus TCP / 4 bis 20 mA E: N1 Modbus TCP / 0 bis 10 V |
Discover the superior quality and performance of the CD AUTOMATION RC3060-45AE0O0011 with Impexron GMBH in Taiwan . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The RC3060-45AE0O0011 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of RC3060-45AE0O0011 :
At Impexron GMBH , we offer the RC3060-45AE0O0011 at competitive prices and with the fastest delivery times across Taiwan . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Impexron GMBH ?
Get Your Quote Today! Ready to enhance your operations with the RC3060-45AE0O0011 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply CD AUTOMATION products, Impexron GMBH is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
SSR Only
CD3000M 2PH/150A/380V/480V/170:265V/SSR/ZC/IF/HB/FAN110V/EM
CD3000M 2 Phases unit 150 Amps / 380V Operating voltage / 480Volts supply voltage 170 to 265 Volts auxiliary power supply SSR Input Zero crossing firing 3 x Internal fuses included Heater Break alarm 110V power supplied fan English Manual
CD3000M 2PH/75A/380V/480V/170:265V/SSR/ZC/NF/HB/110VFAN/EM
CD3000M 2 Phases unit 75 Amps / 380V Operating voltage / 480Volts supply voltage 170 to 265 Volts auxiliary power supply SSR Input Zero crossing firing Without external fuses Heater Break alarm 110V Fan English Manual
44kw CD3000M 3PH
56kw CD3000M 3PH
65kw CD3000M 3PH
CD3000S 1 Phase unit 1PH 45 Amps / Operating voltage not specified / 480V max Voltage 12 to 24 Volts auxiliary power supply SSR Input Zero crossing firing Without external fuses Heater Break alarm with SSR input English Manual
Thyristosteller Serie CD
Scarf Ting; 2 phaser, zero crossing switch
Thyristorsteller Serie S
Current transformer 25A / 0.05A 50-60Hz Ru: 40 ohms Messgenaugikeit: 2% Turns ratio: 500 Temperature range: -40 ... + 70 ° C Connection: flat tabs 6.3mm Dimensions: WxHxD 38x20x48 mm Test voltage pri.-sec .: 4kV Housing: self-extinguishing UL 94-VO incl .: 2x DIN rail adapter for horizontal mounting
CD3200-35A 480V-460V-CL Modular construction consists of: 1x CD3200 drive unit 1xCD3S0035480PA thyristor 1xCD31.CT.50A / 0.05 A current transformer
CD3200-15A-480V-170:265V-0/5V-PA-V-NF-UL
THYRISTOR 240V AC 15A PHASE ANGLE CONTROL 0-5V DC
Thyristor Series CD3000M Type: CD3000M-2 PH-400A-480V-460V-XXX-YYY-HB Configuration (if it is ordered without additional information): XXX: Input 4 ... 20mA YYY: Operating BF8 HB: with partial load failure detection - Alarm relay
Thyristor Series S Type: CD3000S-1PH 35A-480V SSR - Circuit: Einphasensteller, zero crossing switch - Load current: 35 A (T40 ° C), 28A (T50 ° C) - load voltage: up to 480 V - Vdrm: 1200 V - Itsm (10ms): 540 A - I²t (tp = 10 ms): 800 A²s - auxiliary voltage: no - Control: Logic (OFF <1.0 Vdc, ON 3 ... 30 Vdc) 5 Vdc (typ. 14 mA) - Dimensions: 52 x 120 x 120 mm (W) - ideal for heating control with resistive load (zero crossing) - anti-parallel thyristor - CE mark - to save space by integr. heatsink - RC circuit and varistor integrated - LED status indicator - DIN-rail mounting or screw fixing
Thyristor Series S Type: CD3000S-1PH 45A-220V-240V-24VAC-SSR-HB - Circuit: Einphasensteller, zero crossing switch - Load current: 45 A (T40 ° C), 35A (T50 ° C) - load voltage: 240 V - Supply voltage: 24 Vac - Control: Logic (OFF <1 Vdc, ON 5 ... 30 Vdc) - partial load failure: * partial load fault detection from 50 msec. on time * Partial load fault detection from 80% of nominal current * Automatic calibration of the nominal current using a button at 100% control value for about 1 minute - Dimensions: 52 x 120 x 120 mm (W) - ideal for heating control with resistive load (zero crossing) - anti-parallel thyristor - CE mark - to save space by integr. heatsink - RC circuit and varistor integrated - LED status indicator - DIN-rail mounting or screw fixing - incl. Current transformer 50 / 0.05A for DIN rail mounting
Thyristorsteller
Thyristorsteller Serie S Typ: CD3000S-1PH-60A-4BOV-SSR
Thyristirsteller Serie S Typ CD 3000S-2PH-10A-480V SSR
Thyristorsteller S.Nr.: 28469-83122-002
Single-phase thyristor series REVO S, Type: RS1ABCDEFGHIKL
Solid state relays
Single-Thristorsteller series REVO S, Type: RS1ABCDEFGHIKL
Solid state relays
Single-phase thyristor series REVO S, Type: RS1ABCDEFGHIKL
Solid state relays